Error Code F dH
Defrost heater error — defrost sensor did not reach 40°F (5°C) within 80 minutes after defrost start
Moderate
Address soon - your appliance may not work properly
Also displayed as: F dH
How to Fix
- 1
Check the door gasket for damage or gaps that could allow warm air infiltration causing excessive frost accumulation. Replace door gasket if damaged.
- 2
Enter Test Mode 1 (press Main PCB test button once): measure CON9 Pin 5 ~ Pin 13 voltage. Should be 0V in Test Mode 1 (heater off state). If not 0V, replace Main PCB.
- 3
Enter Test Mode 3 (press test button three times): measure CON9 Pin 5 ~ Pin 13 voltage. Should be 112–116V when defrost is forced. If voltage is absent, replace Main PCB.
- 4
Measure Fuse-M resistance (CON9 pins): should read 0 Ω. If open (infinite), replace Fuse-M.
- 5
Measure defrost heater resistance: F1 heater should be 62–70 Ω; F2 heater 144–167 Ω. Infinite resistance indicates open heater — replace heater assembly.
- 6
Measure defrost sensor resistance at CON8 Pin 26 ~ Pin 25: should be approximately 22kΩ at room temperature. If open or shorted, replace defrost sensor.
- 7
If all components test good and voltage is present, explain to customer (possible temporary condition from extended door opening).
Other Error Codes for LRFGC2706D
Humidity sensor error — short-circuit or disconnection of humidity sensor
Freezer icemaker sensor error — short-circuit or disconnection of ice maker sensor
Freezer ice maker kit defect — malfunction of ice maker motor
Refrigerator sensor error — short-circuit or disconnection of refrigerator sensor
Freezer sensor error — short-circuit or disconnection of freezer sensor
Defrost sensor error — short-circuit or disconnection of freezer defrost sensor
Freezer BLDC fan motor error — no feedback signal from fan motor for more than 65 seconds
Condenser (machine room) BLDC fan motor error — no feedback signal for more than 65 seconds